PLIT420 REV. B 11/6/13
4.3000
w/o Grommet
5.350
w/ Grommet
4" Round Back up Alarm
Requires 4 1/2" diameter hole and 1 3/4" clearance behind.
63 SERIES BACK-UP ALARMS
1. CAUTION: All of our DC powered back-up alarms are polarity sensitive. All wires
connected to the positive terminal of the battery should be fused at the battery for their
rated load. Testing the alarm before this fuse is properly installed will void the
warranty on the alarm.
2. Mount the alarm in the rear of the vehicle with the sound opening outward towards the
hazard zone. This alarm is designed to mount in a standard 4½ “ mounting hole.
3. Connect the black wire to the negative side of the battery or a good chassis ground.
4. Connect the red wire to an independent actuating switch or splice it into the back-up lights.
Please Note: The vehicles supply voltage must be the same as the voltage rating
specified on the alarm you are installing. Any other voltage applied will void the warranty.
5. For models with a 3-Wire Cable: The white wire is used for an alternate output. Connect
it to the positive side of your power through the switch that controls the alternate function.
If you have any questions concerning this or any other Star product, or need warranty
service, please contact our Customer Service Department at (585) 226-9787.
ONE YEAR LIMITED WARRANTY
The manufacturer warrants each new product, under normal use, against factory defects in material
and workmanship for one year after the date of purchase. The owner will be responsible for returning
to the Service Center any defective item(s) with the transportation costs prepaid. The manufacturer
will, without charge, repair or replace at its option, products, or part(s), which its inspection determines
to be defective. Repaired or replacement item(s) will be returned to the purchaser with transportation
costs prepaid from the service point. A copy of the purchaser's receipt must be returned with the
defective item(s) in order to qualify for the warranty coverage.
Exclusions from this warranty include, but are not limited to, bulbs, strobe tubes, domes, and/or the
finish. This warranty shall not apply to any light, which has been altered, such that in the
manufacturer's judgment, the performance or reliability has been affected, or if any damage has
resulted from abnormal use or service. This warranty does not apply to defect or damage occurring as
a result of disaster, accident, abuse, misuse, lightning, power surges, or failure to follow instructions in
any enclosed manuals. Any damage or defects occurring as a result of any unauthorized service or
repairs by unauthorized persons shall be excluded from this warranty.
There are no warranties expressed or implied (including any warranty of merchantability or fitness),
which extend this warranty period. The loss of use of the product, loss of time, inconvenience,
commercial loss or consequential damages, including costs of any labor, are not covered. The
manufacturer reserves the right to change the design of the product without assuming any obligation
to modify any product previously manufactured.
This warranty gives you specific legal rights. You might also have additional rights which may vary from
state to state. Some states do not allow limitations on how long an implied warranty lasts. Some states
do not allow the exclusion or limitation of incidental or consequential damages. Therefore, the above
limitation(s) or exclusion(s) may not apply to you.
IMPORTANT: Please read all of the following instructions before installing
your new Star back-up alarm. This instruction sheet applies only for
installation of the models listed above on negative ground vehicles only.
CAUTION: All of our DC powered back-up alarms are polarity sensitive. All wires
connected to the positive terminal of the battery should be fused at the
battery for their rated load. Testing the alarm before this fuse is properly
installed will void the warranty on the alarm.
SPLICE THE RED WIRE FROM THE BACK-UP ALARM INTO
THE WIRE WHICH SUPPLIES POWER TO YOUR REVERSE LIGHT
PRE-EXISTING SWITCH IN VEHICLE ALREADY CONNECTED TO
REVERSE LIGHTS (OFTEN ACTIVATED BY THE GEAR SHIFTER)
REVERSE
LIGHT
BATTERY
GOOD
CHASSIS
GROUND
GOOD
CHASSIS
GROUND
BLACK
WHITE
RED
DF Models: OPTIONAL SWITCH FOR 2nd DEVICE TO ACTIVATE B-U ALARM:
CONNECT THE WHITE WIRE TO +12 VDC FOR ALTERNATE OUTPUT
GOOD
CHASSIS
GROUND
The White wire will only be present on models
with dual function capability (DF models).
Dual Tone units emit an alternating high/low tone.
Auto-Adjusting units will automatically adjust the output volume based upon the ambient noise.